the design of xyt-180-4f series motors is combine water cooling unit of fslp and electromagnetic design of xyt-180-4 series motors , ,which can achieve the maximum power saving effect. the outline and mounting dimensions are the same as fe2sp180-4f series motors.
motor type | rated power | current | rated speed | torque | efficiency | power factor | locked current | locked torque | maximum torque | protection class |
kw | a | r/min | n.m | η% | cosφ | rated current | rated torque | rated torque | ||
xyt180m1-4f | 15 | 25.0 | 1500 | 95.5 | 94.0 | 0.97 | 6.8 | 2.3 | 2.3 | ip55 |
xyt180m2-4f | 18.5 | 30.7 | 1500 | 117.8 | 94.3 | 0.97 | 7.1 | 2.3 | 2.3 | ip55 |
xyt180l1-4f | 22 | 36.4 | 1500 | 140.1 | 94.7 | 0.97 | 6.4 | 2.3 | 2.3 | ip55 |
xyt180l3-4f | 30 | 49.5 | 1500 | 191.0 | 95.0 | 0.97 | 7.6 | 2.3 | 2.3 | ip55 |
for example, changing 18.5kw inverter duty motor into 18.5kw water-cooling permanent magnet synchronous inverter duty three-phase motor, it can save 22(pm) 20(water-cooling)=42 kilowatt – hour. if the motor can be used for 5 years and 300 working days per year , then during operation period it can save 42*300*5=63000 kilowatt – hour, 63000x0.50=31500 rmb , this money is enough to purchase more than 4 pcs new motors , and 5~6 months is enough to recover increased investment.